IEC 61156-2-1:2010 pdf download – Multicore and symmetrical pair/quad cables for digital communications Part 2-1: Horizontal floor wiring – Blank detail specification
1 Scope
This blank detail specification relates to multicore and symmetrical pair/quad cables for digitalcommunications in horizontal floor wiring.
This blank detail specification determines the layout and style for detail specificationsdescribing multicore and symmetrical pairlquad cables for digital communication in horizontalfloor wiring. Detail specifications based on the blank detail specification may be prepared by anational standards organization, a manufacturer or a user.
2Normative references
The following referenced documents are indispensable for the application of this document.Fordated references,only the edition cited applies. For undated references, the latest edition ofthe referenced document (including any amendments) applies.
IEC 61156-1:20021),Multicore and symmetrical pairlquad cables for digital communications -Part 1: Generic specification
IEC 61156-2:2010,Multicore and symmetrical pairlquad cables for digital communications -Part 2: Symmetrical pairlquad cables with transmission characteristics up to 100 MHz -Horizontal floor wiring – sectional specification
3 Guidance for preparation of detail specifications
lt is necessary to keep the transmission characteristics indicated in the relevant sectionalspecification for the category number(3 or 5) and the characteristic impedance.
NOTE When a characteristic does not apply, then NA (for Not Applicable) may be entered in the appropriatespace.
When a characteristic applies but a specific value is not considered necessary, then NS (for Not Specfied shouldbe entered in the appropriate space.
The numbers shown in brackets in this and the following pages correspond to the following items of required information which shall be entered in the spaces provided.
[1 ] Name and address of the organization that has prepared the document.
[2] IEC document number, issue number and date of issue.
[3] Address of the organization from which the document is available.
[4] Related documents.
[5] Any other reference to the cable, national reference, trade name, etc.
[6] A complete description of the cable:
a) type and number of elements;
b) nominal impedance;
c) screening;
d) application;
e) category;
f) other distinguishing performance characteristics.
Example: Detail specification for 4-pairs cable without common screen for digital communications in horizontal floor wiring category 5.
[7] Details of the cable materials and construction.
[8] Special requirements for bending radius or operation temperatures.
[9] List of cable characteristics. They are separated into electrical, transmission, mechanical and environmental characteristics.
[1 0] Appropriate subclause references in the sectional specification IEC 61 1 56-2.
[1 1 ] Requirements applicable for this cable. The values entered shall at a minimum meet the requirements of sectional specification IEC 61 1 56-2.
[1 2] Relevant remarks.