IEC 60317-1:2010 pdf download – Specifications for particular types of winding wires – Part 1: Polyvinyl acetal enamelled round copper wire, class 105
This Part of IEC 6031 7 specifies the general requirements of enamelled round copper winding wires of class 1 05 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics. Class 1 05 is a thermal class that requires a minimum temperature index of 1 05 and a heat shock temperature of at least 1 55 °C. The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved. The range of nominal conductor diameters covered by this standard is as follows: – Grade 1 : 0,040 mm up to and including 2,500 mm; – Grade 2: 0,040 mm up to and including 5,000 mm; – Grade 3: 0,080 mm up to and including 5,000 mm. The nominal conductor diameters are specified in Clause 4 of IEC 6031 7-0-1 .
2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 6031 7-0-1 :2008, Specifications for particular types of winding wires – Part 0-1: General requirements – Enamelled round copper wire 3 Terms, definitions and general notes on methods of test and appearance
3.1 Terms and definitions For terms and definitions, see 3.1 of IEC 6031 7-0-1 . In case of inconsistencies between IEC 6031 7-0-1 and this standard, IEC 6031 7-1 shall prevail.
3.2 General notes on methods of test For general notes on methods of test, see 3.2 of IEC 6031 7-0-1 . In case of inconsistencies between IEC 6031 7-0-1 and this standard, IEC 6031 7-1 shall prevail.
.3 Appearance
See 3.3 of IEC 6031 7-0-1 .
4 Dimensions
See Clause 4 of IEC 6031 7-0-1 .
5 Electrical resistance
See Clause 5 of IEC 6031 7-0-1 .
6 Elongation
See Clause 6 of IEC 6031 7-0-1 .
7 Springiness
See Clause 7 of IEC 6031 7-0-1 .
8 Flexibility and adherence
See Clause 8 of IEC 6031 7-0-1 , where the constant K used for the calculation of the number of revolutions for the peel test shall be 1 75 mm.
9 Heat shock
The minimum heat shock temperature shall be 1 55 °C.
9.1 Nominal conductor diameters up to and including 1 ,600 mm
The coating shall show no crack. The mandrel diameter shall be as specified in Table 1 .
13 Breakdown voltage
See Clause 1 3 of IEC 6031 7-0-1 , where the elevated temperature shall be 1 05 °C.
14 Continuity of insulation
See Clause 1 4 of IEC 6031 7-0-1 .
15 Temperature index
See Clause 1 5 of IEC 6031 7-0-1 , where the minimum temperature index shall be 1 05.
16 Resistance to refrigerants
Test appropriate but no requirements are specified.
17 Solderability
Test inappropriate.
18 Heat and solvent bonding
Test inappropriate.
19 Dielectric dissipation factor
Test inappropriate.
20 Resistance to transformer oil
Test appropriate but no requirements specified.
21 Loss of mass
Test inappropriate.
23 Pin hole test
See Clause 23 of IEC 6031 7-0-1
30 Packaging
See Clause 30 of IEC 6031 7-0-1 .